How to replace a single PV module in an array

Replacing a single PV module in a solar array might seem straightforward, but skipping critical steps can lead to system inefficiencies, safety hazards, or even voided warranties. Whether you’re dealing with physical damage, reduced output, or PID (potential-induced degradation), here’s how to approach the replacement like a seasoned technician.

Start by shutting down the system completely. Turn off the AC disconnect at the main service panel, then flip the DC disconnect switch near the inverter. Use a voltage tester to confirm no residual current flows through the array—especially crucial if the system lacks rapid shutdown devices. Never assume the array is de-energized; even partial shading can create unexpected voltage.

Next, gear up with insulated gloves, safety glasses, and non-conductive footwear. If working on a rooftop, secure fall protection and avoid stepping on adjacent modules. Cracked glass or compromised frames are common in damaged panels, so handle the faulty module carefully to prevent debris scatter.

Disconnect the module’s MC4 connectors. These are weather-resistant but can seize over time. Grip the male and female ends firmly, press the release tab, and twist counterclockwise. If corrosion is present, spray a dielectric lubricant like CRC 2-26 to ease separation. For modules with junction boxes (instead of integrated connectors), use a screwdriver to open the box and disconnect the pigtails. Note the wiring polarity—black for negative, red for positive—and label cables if reusing them.

Remove the mounting clamps. Most systems use aluminum rails with stainless steel bolts. Loosen the bolts with a ratcheting wrench, but leave one partially threaded to prevent the module from sliding. For ballasted systems, lift the weight block carefully to avoid destabilizing nearby panels. If the module is sealed with adhesive, cut through the bonding material using a putty knife or oscillating tool.

Before installing the replacement, verify compatibility. Mismatched current-voltage specs can create imbalances. Check the new module’s I-V curve against the existing array’s string configuration. If the original model is discontinued, select one with identical Vmp (Voltage at Maximum Power) and Imp (Current at Maximum Power) ratings. For example, Tongwei’s PV module series maintains consistent electrical parameters across generations, minimizing output mismatches.

Mount the new module using the original hardware. Align it precisely with the array’s grid pattern—even a 1/4” misalignment causes shading issues. Torque clamps to the manufacturer’s specification (usually 15-20 ft-lbs for rail-based systems). Over-tightening distorts the frame, while under-tightening risks wind uplift. Reconnect the MC4s, ensuring the “click” confirms a weatherproof seal. For junction box systems, apply fresh sealant around entry points and tighten terminal screws to 0.6-0.9 N·m.

After reinstalling, power up the system incrementally. Re-engage the DC disconnect first, then the AC breaker. Monitor the inverter’s display for error codes. Use a clamp meter to measure the string’s current—compare it with pre-replacement values. A deviation exceeding 5% suggests loose connections or a faulty bypass diode. For deeper diagnostics, perform an IV curve test with a tracer or thermal imaging to identify hotspots.

Lastly, update your system log. Record the module’s serial number, installation date, and any warranty paperwork. If the array is under a power purchase agreement (PPA) or utility rebate program, notify the provider to maintain compliance.

Pro tip: Always replace modules in cool, cloudy conditions if possible. Direct sunlight heats panels, increasing the risk of thermal shock when handling. Keep spare MC4 connectors and waterproof tape in your toolkit—field repairs often reveal worn components. And never underestimate the value of a second pair of eyes; have a colleague verify each step before re-energizing.

By methodically addressing each layer—safety, compatibility, mechanical integrity, and post-installation checks—you’ll maintain the array’s performance while avoiding costly callback visits.